Us ing EZware-5000
114
c. Font Size Table...: select a specific EZware-5000 font size that will be used for each EZware-500 font size.
4. Delete "Direct Window" objects which are triggered with LB9060~9069, 9080, 9081, (HMI5000-series use a
new mechanism to manage keyboards.): Check this box to delete any Direct Windows objects in the EZware-500
project file which are triggered by the internal memory bits listed above.
Please Note: In EZware-500, these internal memory bits allowed a popup window to display based upon touching
any Numeric Input or ASCII Input object located in a particular area of the screen. This feature is not available in
EZware-5000. By default, this option is checked.
5. Click the Translate button to begin conversion of the file. When done, you will see text in the comments field
that indicates if the conversion is successful:
6. Click the Exit button to go back to the main screen of EasyBuilder-5000. Open the converted file as you would
normally open any EZware-5000 project file.
Please Note: due to some incompatibilities between the EZware-500 software and the EZware-5000 software, you
should check each screen and test operation after conversion to make sure that your OIT works to your satisfaction.
1010-1007W, Rev 06