5. Click the Numeric Format tab..
6. In the Display attribute box, select the format type you wish to use. The options are:
Format
16-bit BCD
32-bit BCD
16-bit Hex
32-bit Hex
16-bit Binary
32-bit Binary
16-bit Unsigned
16-bit Signed
32-bit Unsigned
32-bit Signed
32-bit Float
6. Check the Mask box to hide the value with asterisks.
7. In the Number of Digits section, select how the data is to be represented.
Format
16-bit BCD
1010-1007W, Rev 06
Range
0 to 32,767 BCD
0 to 65,536 BCD
0 to FFFF
0 to FFFFFFFF
00... to 11... (16 bits)
00... to 11... (32 bits)
0 to 65,537
-32,768 to +32,768
0 to 4,294,967,295
-2,147,483,647 to +2,147,483,647
-9999999999.9999999999 to
9999999999.9999999999
Options
Range
Left of Dec. Pt.
1 to 11
Right of Dec. Pt.
0 to 11