InfiniBand Switch Platform Hardware User Manual
IS5300
S1
Mellanox
S2
S3
P1
S4
S5
P3
S6
S7
S8
P5
S9
12. Slide the chassis onto the shelf and determine the location of the upper brackets, on
the vertical supports on the connector side of the chassis.
13. Confirm that the caged nuts for the faceplate are in the correct location.
14. Slide the chassis out just far enough to install the upper brackets. See Figure 22.
Mellanox Technologies
Figure 21: Face Plate Mounting Bolt Locations
F1
F2
IS5300
Mellanox
IS5300
IS5300
Mellanox
Do not move the forklift away from the rack just yet.
Figure 22: Upper Bracket Installation
Holes in the faceplate for mount-
ing on the rack.
The holes are separated by 4U
units
P2
P4
P6
This hole is 60cm up from
the top of the shelf.
Use the socket wrench
with both extensions to
tighten these bolts.
33