InfiniBand Switch Platform Hardware User Manual
If you need to hot swap spine #1 or spine #2:
1. Check to see if the spine you need to remove is connected to the master management
module. See Figure 40.
2. Follow the steps in Section below.
Extracting Spine Boards Except #1 or #2
1. Run the shut down command
down spine 06 run the command below.
switch [master] (config) # no power enable S06
2. Push outward on the ejector handles to unlock the ejectors from the chassis.
3. Open the ejectors until they are at a 45 degree angle from the module.
4. Pull out the module half-way through the guiding rails using both ejectors.
5. Lock the ejector handles.
6. Hold the body of the board on both sides and remove it from the chassis.
Mellanox Technologies
If you have only one management module, the chassis will crash!
"no power enable <module>".
Do not use the fan FRU handle to extract the spine board.
For example to shut