InfiniBand Switch Platform Hardware User Manual
nection between the chassis of the switch and the rack. Test the ground using an Ohm
meter.
ESD connector
1.7
Power Connections
The switch includes integrated hot-swap power supplies which support up to 6 load-shar-
ing 1000W. The slots for the power supply units (PSUs) are on the spine side. The left
side has odd numbered PSUs and the right side has even numbered PSUs. Each PSU has
a dedicated AC inlet. This design enables the optional use of separate main and backup
AC feeds. The input voltage is Autorange, 100-240 VAC, 50Hz or 60Hz. The output
voltage for the PSUs is 48V. The power cords should be standard 3-wire AC power cords
including a safety ground.
Mellanox Technologies
Figure 30: Ground Connection
F1
IS5300
S1
Mellanox
S2
S3
P1
S4
S5
P3
S6
S7
S8
P5
S9
F2
IS5300
Mellanox
IS5300
IS5300
Mellanox
Ground Post
P2
P4
P6
39