Figure 20: Offset To Upper Bracket Bolts; Figure 21: Lock-Down Bar - Mellanox Technologies MIS5600Q-10DNC Installation Manual

648 port infiniband qdr switch platform
Hide thumbs Also See for MIS5600Q-10DNC:
Table of Contents

Advertisement

Rev 2.1
14.
Slide the chassis onto the shelf until the face plate of the chassis touches the vertical rack
support.
15.
Make sure the upper brackets are installed in their correct location.
16.
Screw the bolts through the faceplate into the caged nuts, and tighten all 14 bolts and nuts.
17.
For each offset and upper bracket, screw six bolts through the offset into the upper bracket.
Use one flat washer and one lock washer for each of these bolts.
18.
Place the front lock-down bar at the edge of the chassis and align the holes in the lock-down
bar with the holes in the shelf. Screw down the lock-down bar.
30

Figure 20: Offset to Upper bracket Bolts

Figure 21: Lock-Down Bar

These holes are to
screw the bar into the
shelf
Chassis Installation
These holes are to
screw the bar into the
Chassis