Power Supply, Management Board, And Spine Board Indicator Status At Power On; Figure 34: Spine Side Panel Display Status Indications; Figure 35: Management Module Status Indications For Normal Operation - Mellanox Technologies MIS5600Q-10DNC Installation Manual

648 port infiniband qdr switch platform
Hide thumbs Also See for MIS5600Q-10DNC:
Table of Contents

Advertisement

Rev 2.1
6.1
Power Supply, Management Board, and Spine Board Indicator Status
at Power ON
It can take up to 5 minutes to boot up the system. During this time the status LEDs may
be RED. Turn off the system if any LEDs remain red for more than 5 minutes.
As the power is turned on, you should observe the following conditions for normal operation:
1.
Power Supply Unit(s) AC OK and DC OK indicators are ON and FAIL indicators are OFF.
2.
There is a green Status LED per spine board, per leaf board, and per management module
that indicates power supplies are good.
3.
Spine Board indicators will display status of internal links to the installed leaf boards. All
PHY links to existing leaf Boards should be ON.
4.
Check the Spine LEDs and make sure they coincide with Table 34.
5.
Check the Spine LEDs and make sure they coincide with Table 35.

Figure 35: Management Module Status Indications for Normal Operation