Installation and Setup

This section explains how to install, connect, and optimize the projector display.

Site requirements

To safely install and operate the projector, the installation location must have restricted access for
authorized personal only and meet these minimum requirements.

Physical operating environment

Maximum Ambient Temperature (operating) 35°C (95°F)
Minimum Ambient Temperature (operating) 10°C (50°F)

External exhaust ducting

The installation site must provide a minimum of 450 CFM (ft 3/min) external exhaust airflow to
ensure adequate cooling of the Xenon arc lamp at less than or equal to 25°C (77°F) ambient and
less than 3,000 ft (914.4 m) elevation. Above 25°C or 3,000 ft, 600 CFM is required.

Power connection

The requirements listed below are applicable for permanently wired installation or power cord
connection:
Terminal block, electrician hard-wired to the projector head.
Electrical rating: 200 - 240 VAC, 23 A max.
This product can be connected to an IT power distribution system.

Tools required for installation

12" screwdrivers: Phillips #2 (magnetic) and flat
19mm and 7/8" wrenches
Assorted Allen keys (metric)
Christie approved protective safety clothing if working with the lamp
Lens cleaning tissue and solution