Site requirements
To safely install and operate the projector, the installation location must have restricted access for
authorized personnel only and meet these minimum requirements.
Physical operating environment
Provides specifications for the operating environment.
•
Ambient temperature (operating) up to 500 m (1640.42 ft):
•
Type A: 10 to 24°C (50 to 75°F) at full power and at reduced power above 24°C (75°F)
•
Type B: 10 to 30°C (50 to 86°F) at full power and at reduced power above 30°C (86°F)
•
Type C, D, E : 10 to 35°C (50 to 95°F) at full power
•
Humidity (non-condensing) 20 to 80%
•
Operating altitude: 3,000 m (10,000 ft) maximum at 10 to 25°C (50 to 77°F) ambient
Power connection
A 15A rated wall breaker is required at the installation of the projector.
Ensure a qualified electrician connects the AC power to the laser illumination source and chiller as per
electrical codes.