30 April, '89
Caution: Always lower the top unit [A] before tightening the development unit mounting screw
[B]. The slot [C] on the top unit fits over the positionig pin [D] on the
development unit to correctly position the development unit.
f)
Close the top unit, and secure the development unit (1 screw).
Open the top unit again and reinstall the development unit cover.
g)
24.
Load a toner cartridge [E] as follows:
a)
Hold a new toner cartridge level and shake it well.
b)
Turn down the toner cartridge lever [F].
c)
Insert a new toner cartridge and raise the toner cartridge lever.
(Only load one toner cartridge.)
d)
Cut the green tape and push down the latch on the shutter plate.
Then, pull the shutter plate all the way out.
e)
Hold the green tab and pull the toner seal out as far as it will
go.
f)
Push the shutter plate back in completely.
Close the top unit.
g)