ELECTRICAL OPERATION

1. Interface with The Copier and AC Power

The sorter
has its own CPU which controls all of
communicates with the copier through a
The sorter
Fiber optic cables are used for the serial interface bus because they are
unaffected by electrical noise.
When the main switch is turned on, the copier applies 100 volts ac to the sorter. A
step-down transformer supplies 29 volts ac and 8 volts ac.
The 29-volt and 8-volt ac inputs go to full wave rectifiers on the main
board.
The dc voltages output by these rectifiers are regulated to +24
volts and +5 volts respectively.
9-15
30
April, '89