11/03
Cause:
Checksum error encountered while reading out program memory on TM.
Remedy:
- Check whether the permissible ambient temperature has been observed for the TM .
- Replace TM.
A35805
TM: Checksum EPROM not correct
Cause:
Internal parameter data corrupted.
Remedy:
- Check whether the permissible ambient temperature has been observed for the module.
- Replace module.
A35806
TM: Initialization
Cause:
An error occurred on the TM during initialization.
Remedy:
none
A35807
TM: Process control Watchdog
Cause:
Error timeout Process control on TM
Remedy:
Replace TM.
F35820 -
TM DRIVE-CLiQ: Telegram faulted
F35825
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check cabinet design and cabling for EMC conformity.
- Replace affected component.
See also: p9916
Acknowl.:
Immediate
F35826
TM DRIVE-CLiQ: fault in cyclic data transfer
F35827
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace Control Unit.
Acknowl.:
Immediate
F35828
TM DRIVE-CLiQ: Receive ALARM bit
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.:
Immediate
F35829
TM DRIVE-CLiQ: Fault in cyclic data transfer
F35830
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
- Check firmware states of affected components.
- Replace affected component.
See also: p9916
Acknowl.:
Immediate
F35831
TM DRIVE-CLiQ: Telegram faulted
Reaction:
OFF2
Cause:
There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy:
Replace affected component.
Acknowl.:
Immediate
SINAMICS G150
Operating Manual
Diagnosis / Faults and Alarms
10-49