Technical Data
12.2

General Data

Table 12-1
General technical data
Electrical data
Power frequency
Output frequency
Power factor
Fundamental mode
Total
Converter efficiency
Switching at input
Mechanical data
Degree of protection
Type of cooling
Sound pressure level
Shock-hazard protection
Cabinet system
Paint finish
Compliance with standards
Standards
CE marking
Electromagnetic
compatibility
RI suppression
Ambient conditions
Ambient temperature
Humidity range
(non-condensing)
Corresponds to class
Site altitude
Mechanical stability
Vibratory load:
Deflection
Acceleration
Corresponds to class
Shock load:
Acceleration
Corresponds to class
12-2
47 Hz to 63 Hz
0 Hz to 83 Hz
≥ 0.98
0.93 to 0.96
> 98 %
Once every 3 minutes
IP 20 (higher degrees of protection up to IP 54 optional)
Forced air cooling
≤ 72 dB(A) at 50 Hz line frequency
≤ 75 dB(A) at 60 Hz line frequency
BGV A2
Rittal TS 8, doors with double-barb lock
RAL 7035 (indoor requirements)
EN 60 146-1, EN 61 800-2, EN 61 800-3, EN 50 178, EN 60 204-1, EN 60 529
According to EMC directive No. 89/336/EC and low voltage directive No. 73/23/EC
RI suppression filter according to EN 55 011, Class A1, available as option (for
TN/TT systems)
According to EMC product standard for variable-speed drives EN 61 800-3
(restricted distribution)
Operation
0 °C to +40 °C
Up to + 50 °C with
derating
5 % to 95 %
3K3 to IEC 60 721-3-3
Up to 2000 m above sea level without derating,
> 2000 m above sea level with derating, see Section 12.2.1
0.075 mm at 10 Hz - 58
Hz
10 m/s² at > 58 Hz - 200
Hz
-
100 m/s² at 11 ms
3M4 to IEC 60 721-3-3
Storage
-25 °C to +55 °C
5 % to 95 %
1K4 to IEC 60 721-3-1
1.5 mm at 5 Hz - 9 Hz
5 m/s² at > 9 Hz - 200 Hz
1M2 to IEC 60 721-3-1
40 m/s² at 22 ms
1M2 to IEC 60 721-3-1
11/03
Transport
-25 °C to +70 °C
Above –40 °C for 24 hours
5 % to 95 % at 40 °C
2K3 to IEC 60 721-3-2
3.5 mm at 5 Hz - 9 Hz
10 m/s² at > 9 Hz - 200 Hz
2M2 to IEC 60 721-3-2
100 m/s² at 11 ms
2M2 to IEC 60 721-3-2