6.4 Cluster Administration Troubleshooting

6.4.1 Monitor and Debug Command List

6.4.1.1 show cluster
Command: show cluster
Function: Display the basic information of the member or command switch
Parameter: None
Default: None.
Command mode: Admin Mode
Usage Guide: The system will process this command separately for command switch,
member switch and candidate switch.
Example:
1. Show cluster information on the command switch.
Switch#show cluster
Command switch for cluster CLUSTER
Total number of members: 4
Status: 0 Inactive
Time since last status change: 2 hours, 34 minutes, 25 seconds
Heartbeat interval: 10 seconds
Heartbeat hold-time: 100 seconds
2. Show cluster information on the member switch.
Switch#show cluster
Member switch for cluster CLUSTER
Member Number: 3
Management IP address: 192.168.1.64
Command switch mac address: 00-03-0f-00-28-e6
Heartbeat interval: 10 seconds
Heartbeat hold-time: 100 seconds
Status: Active
3. Show cluster information on the candidate switch.
Switch#show cluster
Candidate switch
Register timer: 60 seconds
Description:
For the command switch
Command switch for cluster <clustername>
Total number of members
Status
DCS-3950 series Ethernet switch manual
Description
Cluster name and role, <clustername> is
the name of the cluster.
Number of members in the cluster.
Status of the cluster's members, and
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents