NTI SERVER ENVIRONMENT MONITORING SYSTEM

Liquid Detection Sensor

NTI Model #.................................................... ENVIROMUX-LDS
Connector ......................................................RJ45 connector
Minimum Liquid depth ...................................0.1"
Detectable Liquids .........................................All except de-ionized water; all conductive liquids
Voltage Supply...............................................12V DC
Current Consumption.....................................20mA
Max. Cable Length.........................................1000 ft
Minimum puddle ............................................0.6" diameter, 0.1" depth
Communication Type .....................................Contact, 2-wire

Smoke Sensor

NTI Model #.................................................... ENVIROMUX-SDS
Connector ......................................................Screw Terminal
Voltage Supply...............................................8 - 35V DC
Current Consumption.....................................200uA
Alarm Output..................................................Relay (NO)
Max. Cable Length.........................................1000 ft

Vibration Sensor

NTI Model #.................................................... ENVIROMUX-VSS
Connector ......................................................Screw Terminal
Alarm Output..................................................NO
Max. Cable Length.........................................1000 ft

Motion Sensor

NTI Model #.................................................... ENVIROMUX-IMD-CM (Ceiling Mount)
...................................................ENVIROMUX-IMD (General Model)
.................... ...........................ENVIROMUX-IMD-MW (Miniature)
Connector ......................................................Screw Terminal
Voltage Supply...............................................8 - 16V DC
Current Consumption.....................................15mA
Alarm Output..................................................Relay (NC), 10 ohm in-line resistor, 28VDC/100mA
Tamper Switch...............................................NC dry contact, 10 ohm in-line resistor, 28VDC/50mA
Max. Cable Length.........................................1000 ft
Operating Temperature..................................-10˚C to 55˚C
Humidity.........................................................95%, Non-Condensing

Glass Break Sensor

NTI Model #.................................................... ENVIROMUX-GBS
Connector ......................................................Screw Terminal
Voltage Supply...............................................9 - 16V DC
Current Consumption.....................................35mA
Alarm Output..................................................Form A relay (NC or NO), 1A/24VDC
Alarm Duration...............................................3 seconds
Max. Cable Length.........................................1000 ft