CONTROL BOARD REMOVAL / INSTALLATION
CONTROL BOARD REMOVAL
CAUTION: If burner and/or pilot have been burning, use appropriate protection to
avoid burns or personal property damage before removing any components.
1.
911XL / 911XL-RAD: Turn gas control knob to OFF.
911XL-IPI: Use remote to turn fireplace off.
2.
Shut off gas supply at manual shut-off valve.
3.
Disconnect gas line flex tube from manual shut-off valve.
4.
911XL / 911XL-RAD: Disconnect any wall switch, remote control, or
911XL-IPI: Unplug all components from electrical outlet, disconnect all wiring
harnesses attached to gas valve.
5.
Remove glass assembly. Page 9.
6.
Remove logs.
7.
Remove nuts securing burner assembly. Remove burner assembly from firebox.
8.
Remove burner heat shield.
9.
Remove (8) nuts securing control board. Lift board up and out of firebox.
CONTROL BOARD INSTALLATION
WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET
(LOCATED UNDER CONTROL BOARD) IN PLACE.
1.
Place control board in firebox, aligning holes in control board with mounting studs in
firebox bottom. Ensure sealing gasket in in place on firebox bottom!
CAUTION: Before securing, check that all wires are clear and unobstructed. Do not
allow any wires or gas flex line to come in contact with fan terminals.
Secure control board to firebox bottom with (8) 1/4" nuts. Place burner heat shield
over control board (flanges facing down).
2.
Install burner assembly; burner tube is positioned over burner orifice, and alignment
slots are place over mounting studs on control board. Secure with 1/4" nuts.
3.
Install pilot shield around pilot assembly.
4.
Connect gas line to manual shut-off valve.
5.
911XL / 911XL-RAD: Connect any wall switch, remote control or thermostat
wires to terminals on valve marked TH / THTP.
911XL-IPI: Reconnect all wiring harnesses to gas valve. Plug components into
electrical outlet.
6.
Install log set. Page 22.
7.
Install glass frame assembly. Page 9.
8.
Verify proper log placement, operation of insert and any electrical components.
CAUTION: CHECK ALL CONNECTIONS FOR LEAKS, WHETHER FIELD OR FACTORY
MADE.
thermostat wires from TH / THTP terminals on gas valve.