1. Run the gas line. An accessible shut off valve must be installed up stream from the regulator.
NOTE: Do not run the incoming gas line in a manner that would obstruct the operation of the fan.
2 . This fireplace is designed to accept either a 3/8" or 1/2" gas line approved for gas appliances.
Consult local building codes to properly size the gas supply line leading to a 3/8" reduction.
3. A gas line knockout is positioned on either side of the fireplace for gas line connection.
4. Connect the gas line to the manual shut-off valve.
5. Connect the flexible gas line (installed on the millivolt board valve) to the manual shut off
valve.
ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE MUST BE
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi.
Pressure check taps for both the manifold (outgoing) & inlet (incoming) pressures are located in front of the gas valve.
The top pressure tap is the manifold pressure and the bottom pressure tap is the incoming pressure. Follow instructions
on page #22 for checking these pressures.
(H) SECURE THE MILLVOLT BOARD:
This fireplace is equipped with the millivolt board & burner / cover assembly already installed. Referring to the
'INSTALLING THE MILLIVOLT BOARD' section on pages #24-#25, check to ensure that all (7) nuts securing the
millivolt board are in place and properly tightened. Re-install the burner / cover assembly, securing it to the
millivolt board bottom with the (2) nuts provided and ensuring the burner tube is properly positioned over the
burner orifice.
IMPORTANT:
CHECKED FOR LEAKS!