2. This fireplace is designed to accept either a 3/8" or 1/2" gas line approved for gas appliances. Consult local building
codes to properly size the gas supply line leading to a 3/8" reduction.
3. A gas line knockout is positioned on either side of the fireplace for gas line connection.
4. Connect the gas line to the manual shut-off valve.
5. Connect the flexible gas line (installed on the millivolt board) to the manual shut off valve.
IMPORTANT:
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas valve. The right
pressure tap is the manifold pressure and the left pressure tap is the incoming pressure. FOLLOW INSTRUCTIONS ON PAGE
#24 OF THIS MANUAL.
G) MILLIVOLT BOARD & BURNER ASSEMBLY REMOVAL / INSTALLATION - Figures 11A-11E.
NOTE: This fireplace is equipped with the millivolt board and burner plate already installed. Ensure that all of
the nuts are tightened, securing the board to the firebox. Follow these procedures in the event this
assembly needs to be removed for service and/or maintenance.
MILLIVOLT BOARD REMOVAL.
1. Open the lower grill to access the gas valve
and controls.
2. Turn the control knob to 'OFF'.
3. Remove the front upper grill, glass assembly,
log set, rock wool embers & log grate. Figure 11A.
4. Shut off the gas supply at the manual shut-off valve.
5. Disconnect the flexible gas line tube from the
manual shut-off valve.
6. Disconnect any wall switch, remote control or
thermostat wires from the valve.
7. Loosen and remove the (2) ¼" nuts securing the
burner cover. Figure 11B.
8. To release the adjustable venturi collar at the end of
the burner tube, gently push back the mounting bracket
only far enough to release the collar. Figure 11B.
9. Remove the burner cover from the firebox.
ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE MUST
BE CHECKED FOR LEAKS!
Figure 11B
Page 14
LOG GRATE
Figure 11A
1/4" NUTS SECURING BURNER COVER