4. If necessary level the unit by threading the leveling bolts (included in the components packet) into the nuts
mounted in the bottom of the insert behind the lower air passage - 2 each side. See Figure F-5.
Figure F-5
G.

Complete the gas line installation

1. This fireplace is designed to accept either a 3/8" or 1/2" gas line approved for gas appliances.
Consult local building codes to properly size the gas supply line leading to a 3/8" reduction.
2. Run the gas line into the fireplace, preferably through the left gas line hole. A gas line knock-out
is also located in the outer bottom of the insert when running the gas line through the bottom.
IMPORTANT:
3. Install the manual shut off valve (included with this fireplace) upstream from the regulator.
4. Connect the flexible gas line (installed on the gas valve on the millivolt board) to the manual shut
off valve.
H.

Check millivolt board installation:

NOTE:
Refer to pages #26 & #27 in this installation manual for complete millivolt board installation
procedures.
1. Ensure that all (6) nuts are attached to the mounting studs, securing the millivolt board in position.
2. Verify that the burner venturi is properly positioned over the burner orifice and the burner /cover
assembly is secured to the burner heat shield.
3. Check all gas connection for leaks, whether field or factory made.
:
Do not run the incoming gas line in a manner that would obstruct the operation
of the fan.