Chapter 7 Troubleshooting; Check List - Fujitsu ETERNUS DX100 S3 Operation Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX100 S3:
Table of Contents

Advertisement

Chapter 7
Troubleshooting
This chapter explains troubleshooting when errors occur.
If something unusual occurs during operation (such as the instances listed below), refer to
(page 104)
to check the ETERNUS DX status, and contact your maintenance engineer according to
quired Information for Inquiries" (page
When the ETERNUS DX is turned off
When the ETERNUS DX refuses to turn on
When the READY LED is not on
When the FAULT LED is on
When the FAULT LED blinks
When the DISK FAULT LED is on
When the ETERNUS DX cannot be connected via a network service
When I/O access is slow
When the server does not recognize the volumes
When a Server HBA Fails and Needs to be Replaced
7.1

Check List

When the ETERNUS DX is Turned Off
Check the points that are shown below. If the problem cannot be resolved, leave the ETERNUS DX alone and
contact your maintenance engineer.
Is the ETERNUS DX's power cord disconnected?
Is PSU switch of the power supply unit turned to OFF (¡)?
Has the server been turned off?
If the ETERNUS DX power is in conjunction with the power synchronized unit, the power of the ETERNUS DX
will turn off when the server is turned off.
Is the main line switch of the power distribution unit turned OFF (¡)?
Is there a power failure?
Has there been a recent main power failure?
If the Power Resume function is enabled, the ETERNUS DX turns on automatically after the power is re-
stored.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
112).
104
Copyright 2014 FUJITSU LIMITED
"7.1 Check List"
"7.2 Re-
P3AM-7662-04ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx200 s3

Table of Contents