Fujitsu ETERNUS DX100 S3 Operation Manual page 106

Disk storage system
Hide thumbs Also See for ETERNUS DX100 S3:
Table of Contents

Advertisement

Chapter 7
Troubleshooting
7.1
Check List
2
Connect the mini SAS HD cable between enclosures while the drive enclosure is on.
3
Press the controller enclosure's Power switch to turn on the ETERNUS DX.
When the l (IN) and n (OUT) side of the mini SAS HD cable between enclosures is incorrectly connected
or the cable is connected in the wrong order
1
Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX, and
turn off the AC power.
2
Reconnect the mini SAS HD cable between enclosures.
3
Make sure that AC power is being supplied, then turn the ETERNUS DX on.
When the FAULT LED Blinks
Check the general status and the system messages in ETERNUS Web GUI. A general status of
cates that the ETERNUS DX contains a component that requires preventive maintenance.
In the details screen for each component, check the detailed information for each component with the
symbol and contact your maintenance engineer.
For details about how to check the general status via ETERNUS CLI, refer to
NUS CLI" (page
When the DISK FAULT LED is On
Check the drive status.
While the Protection (Shield) function is being used, the DISK FAULT LED is temporarily turned on. For details
on how the Protection (Shield) function works and how to check whether it is running, refer to "Design Guide
(Basic)".
If none of these resolve the problem, contact your maintenance engineer.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
54).
Copyright 2014 FUJITSU LIMITED
106
indi-
"3.3 Displaying Status via ETER-
P3AM-7662-04ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx200 s3

Table of Contents