Chapter 2
Basic Operation
2.1
Powering On and Off
When turning off the ETERNUS DX, the power shuts off after the write data in the cache memory is writ-
ten back to the drives. As a result, it may take approximately one to six minutes (approximately two to
six minutes in a Unified configuration) for the power supply to be completely turned off.
Do not turn off the power of the ETERNUS DX and the network devices that connect the ETERNUS DX to a
server while the server is operating. This may result in the loss of data or prevent data from being saved
in the ETERNUS DX.
When using a power synchronized unit for power control, turn off the power of the ETERNUS DX via the
power synchronized unit. When a power synchronized unit is connected, the power of the ETERNUS DX is
automatically turned on because the power synchronization function is activated.
After power-off, wait for about one minute before turning power on again.
This section explains how to use the Power switch to turn off the ETERNUS DX.
For other procedures, refer to the related manuals.
1
Press and hold the Power switch of the controller enclosure for four seconds or more.
Power switch
The READY LED on the controller enclosure is turned off.
Press the Power switch only once. If the Power switch is pressed again between the time of the
READY LED turning off and the POWER LED turning off, the ETERNUS DX power may turn on.
2
The ETERNUS DX power is turned off.
The POWER LED of the controller enclosure and the POWER LEDs of the drive enclosures are turned off.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
Controller enclosure
50
Copyright 2014 FUJITSU LIMITED