Table 1.3 Status And Meanings Of Each Led (Controller) - Fujitsu ETERNUS DX100 S3 Operation Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX100 S3:
Table of Contents

Advertisement

Chapter 1
Component Name/LED Name
1.1
Controller Enclosures
2.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a cable between enclosures.
3.
LAN (RMT) port
These are the RJ-45 connectors to connect LAN cables.
4.
LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables.
5.
Host interface (CA#0)
Install host interfaces. For details, refer to
6.
Host interface (CA#1)
Install host interfaces. For details, refer to
7.
IDENTIFY/SCU READY LED
8.
CA#0 FAULT LED
9.
DI (OUT) LINK/FAULT LED
10. READY/FAULT LED
11. CA#1 FAULT LED
12. MASTER LED
13. LINK/FAULT LED
14. LAN ACCESS LED
15. LAN LINK LED
The states of LEDs are listed below.

Table 1.3 Status and Meanings of Each LED (Controller)

LED name
IDENTIFY/SCU READY
DI (OUT) LINK/FAULT
READY/FAULT
MASTER
CA FAULT
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
"■ Host Interfaces" (page
"■ Host Interfaces" (page
LED status
Meaning
(blinks green)
The link between the DI (OUT) port and the destination port has
(green)
been established.
(amber)
The ports to connect the cables are indicated. This occurs while a
(blinks amber)
drive enclosure is being added.
The controller is in normal status.
(green)
An error has occurred during startup.
(blinks green)
(amber)
(blinks amber)
The controller is set as a Master CM.
(green)
The host interface is in error status.
(amber)
21
Copyright 2014 FUJITSU LIMITED
22).
22).
As ordered via ETERNUS Web GUI or ETERNUS CLI, the installa-
tion location of the controller is identified.
System Capacitor Unit (SCU) is charging.
The link between the DI (OUT) port and the destination port is
in error status.
The ports to remove the mini SAS HD cables between enclo-
sures from are indicated. This occurs while a drive enclosure is
being added.
The controller is performing the initial setup after the power is
turned on.
The controller is in error status.
P3AM-7662-04ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx200 s3