Fujitsu ETERNUS DX100 S3 Operation Manual page 89

Disk storage system
Hide thumbs Also See for ETERNUS DX100 S3:
Table of Contents

Advertisement

Chapter 5
Expansion Functions
5.2
Installing Additional Drive Enclosures
11
Disconnect the cables from I/O module line 1.
Remove the cable that connects the DI (OUT) port of CM#1 in the controller enclosure and the DI (IN)
port of IOM#1 in the drive enclosure, which is nearest to the drive enclosure that is to be added.
The following figure shows the cable (between CE and DE) that needs to be disconnected from the en-
closures when drive enclosure 2 is added.
The FAULT LED for the DI (IN) port from which the cable is to be disconnected and the LINK/FAULT LED
for the DI (OUT) port in the controller enclosure turn on.
Drive enclosure 2
(drive enclosure
that is to be added)
Drive enclosure 1
Controller enclosure
12
Click the [Next >>] button.
The [Connect Cable] screen appears.
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
89
Copyright 2014 FUJITSU LIMITED
Remove
from here
Remove
from here
Controller 1
P3AM-7662-04ENZ0