Chapter 9 — Troubleshooting
88
Overall Dark Printout
Possible Cause
Wrong media grade
Contrast value too
high
Printhead pressure too
high
Wrong printhead
voltage
Excessive Bleeding
Possible Cause
Wrong media grade
Contrast value too
high
Printhead pressure too
high
Faulty energy control
Dark Lines Along Media Path
Possible Cause
Foreign objects on
printhead
White Vertical Lines
Possible Cause
Printhead dirty
Missing printhead
Remedy
Change parameter
Change parameter
Adjust
Replace CPU board Call Service
Remedy
Change parameter
Change parameter
Adjust pressure
Replace CPU board Call Service
Remedy
Clean printhead
Remedy
Clean printhead
Replace printhead