RESTRICTOR INSTALLATION
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
installation is complete a restrictor may be required or may need to be removed or modified.
Large Restrictor
Figure 17a
MINIMUM / MAXIMUM HORIZONTAL VENTING
NOTE: Horizontal sections require 1/4" (6 mm) rise for every 12" (305 mm) of travel.
NOTE: Page 17 has information on restrictor installation in conjunction with venting installation. Page 31 has information on
restrictor recommendations depending on burner flame appearance and instructions on installation after venting is completed.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
WARNING: A WALL PASS-THRU MUST BE USED ON ALL HORIZONTAL VENT RUNS.
Figure 17b
VENTING
Bend tabs to approx. 80 degree
Remove tab (s) to
angles to create tension to hold
create small restrictor
itself in place when installed.
MINIMUM: 6 in. (152mm)
MAXIMUM: 20 ft. (6.096 m)
TERMINATION
CAP
PAGE 17
Slide restrictor into exhaust pipe on top of
fireplace with tabs pointing towards you
prior to attaching venting.