2.0 SPECIFICATIONS

2.1 Appliance Components

Part Number
Description
J30-160
Control Board Assembly
700-203
Manual Gas Shut-off Valve
J30-500
Log Package
JOR-057T
Glass Assembly
J34-028
Fan Kit (1)-75 CFM
J30-LKT
Light Kit
700-508
Remote Control
JOR-GLT
Glass Latch Tool
2.1.1 Additional Components Required
2.1.1.1 Shrouds
Part Number
Description
J30-004
Blank shroud
J30-25038
25" x 38" shroud (1 piece)
J30-27542
27-1/2" x 42" shroud (1 piece)
J30-30044
30" x 44" shroud (1 piece)
J30-CUS
Custom shroud (1 piece)
J30-ACUS
Custom Arched shroud (1 piece)
2.1.1.2 Approved Vent Systems
Vent Manufacturer
Kozy Heat
ICC
Selkirk
American Metals (Amerivent)
Olympia Venting Supply, Inc.
Simpson Dura-Vent
Security
Metal Fab
RLH

2.2 Heating Specifications

Natural Gas
Maximum
Input Rating
Minimum
Input Rating
Manifold Pressure
3.8" WC (.95 kPa)
(High)
Manifold Pressure
1.1" WC (.27 kPa)
(Low)
Orifice Size (DMS)
FRONT: 53 BACK: 44
8 SPECIFICATIONS
Approved Caps
#816-CL Co-linear Vent System
TMT-IVT
4DT-VC
4DVC
VDV-VCC33
VDV-CC33
46DVA-VCH
3PDVCV
4DVT
HS-C33U99
HS-C33F1313
HS-CD3333-1313
LP Gas
30,500 Btu/h
30,500 Btu/h
(8.9 kW)
(8.9 kW)
12,000 Btu/h
11,000 Btu/h
(3.5 kW)
(3.2 kW)
11" WC (2.74 kPa)
2.9" WC (.72 kPa)
FRONT: 61 BACK: 55
2.2.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer
to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities,
or codes having jurisdiction in you area regarding derate
guidelines.
2.2.1.1 US Installations
Refer to the American Gas Association guidelines for the gas
designed appliances derating method. For elevations above 2,000
ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft
(305 m) above sea level.
2.2.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500 ft (1,372
m), the certified high altitude rating shall be reduced at the rate of
4% for each additional 1,000 ft (305 m).