Specifications; Appliance Components; Heating Speciications - kozy heat CHASKA 29-ROCK Installation And Operation Manual

Direct vent gas fireplace insert
Hide thumbs Also See for CHASKA 29-ROCK:
Table of Contents

Advertisement

2.0 SPECIFICATIONS

2.1 Appliance Components

Part Number
Description
CK29L-150
Control Board Assembly
700-203
Manual Gas Shut-of Valve
CK29L-135
Burner Assembly
CK34-R500
Rock Kit
701-009T
Glass Assembly
CK29-028
Fan Kit (1)-75 CFM
500-CK29
Grill Assembly
700-408
Remote Control
2.1.1 Additional Components Required
2.1.1.1 Shrouds
Part Number
Description
CK29-004
Blank Shroud (4 pc.)
CK29-2538
25" x 38" shroud (1 pc.)
CK29-27542
27½" x 42" shroud (1 pc.)
CK29-3044
30" x 44" shroud (1 pc.)
CK29A-2838
28" X 38" Arched shroud (1 pc.)
CK29-CUS
Custom shroud
CK29-ACUS
Custom arched shroud
2.1.1.2 Approved Vent Systems
Kozy Heat #816-CL co-linear vent system
For use with minimum 6" x 8" I.D. masonry or 7" I.D. Class A metal
chimneys; includes 12 ft. (3.66 m) compressed, expandable co-
linear 3" x 3" flexible pipes and termination cap.
Other approved vent manufacturers
BDM, American Metals (Amerivent), Metal Fab, Selkirk, Simpson
Dura-Vent, and ICC TM-IVT cap only.
2.2 Heating Specifications
Natural Gas
Maximum
Input Rating
Minimum
Input Rating
Manifold Pressure
3.8" WC (.95 kPa)
(High)
Manifold Pressure
1.1" WC (.27 kPa)
(Low)
Orifice Size (DMS)
8 SPECIFICATIONS
LP Gas
30,500 Btu/h
30,000 Btu/h
(9.0 kW)
(8.8 kW)
16,000 Btu/h
16,000 Btu/h
(4.7 kW)
(4.7 kW)
11" WC (2.74 kPa)
2.9" WC (.72 kPa)
#42
2.2.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer
to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities,
or codes having jurisdiction in you area regarding derate
guidelines.
2.2.1.1 US Installations
Refer to the American Gas Association guidelines for the gas
designed appliances derating method. For elevations above 2,000
ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft
(305 m) above sea level.
2.2.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500 ft (1,372
m), the certiied high altitude rating shall be reduced at the rate of
4% for each additional 1,000 ft (305 m).
#53