HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent
Failure SCSI: Port Y: SCSI ID Z.
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It
may fail at some time in the future.
Action:
•
If this drive is part of a non-fault-tolerant configuration, back up all data
before replacing the drive and restore all data afterward.
•
If this drive is part of a fault-tolerant configuration, do not replace this drive
unless all other drives in the array are online.
1720-S.M.A.R.T. Hard Drive Detects Imminent Failure
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It
may fail at some time in the future.
Action:
•
If configured as a non-RAID 0 array, replace the failing or failed drive. Refer
to the server documentation.
•
If configured as a RAID 0 array or non-RAID setup, back up the drive or
drives, replace the drive, and restore the system.
1721-Slot X Drive Array - Drive Parameter Tracking Predicts
Imminent Failure...
...The following devices should be replaced when conditions permit. Do not replace drive
unless all other drives in the array are on-line! Back up data before replacing drive(s) if
using RAID 0.