1788-Slot X Drive Array Reports Incorrect Drive Replacement - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: Hard drive X failed or cable is loose or defective. Following a
system restart, this message notes that drive X is defective and fault tolerance is
being used.
Action:
1. Be sure all cables are connected properly and securely.
2. Test and replace defective cables.
3. Replace drive X. (depending on the fault-tolerance level, all data may be lost
if another drive fails).

1788-Slot X Drive Array Reports Incorrect Drive Replacement...

...The following SCSI drive(s) should have been replaced: SCSI Port Y: SCSI ID Z.
The following SCSI drive(s) were incorrectly replaced: SCSI Port y: SCSI ID z.
Select F1 to continue – drive array will remain disabled.
Select F2 to reset configuration – all data will be lost.
Audible Beeps: None
Possible Cause:
Replacement drives may have been installed in the wrong drive bays.
A bad power cable connection to the drive, noise on the data cable, or
defective SCSI cable exists.
Action:
If replacement drives are installed in the wrong bays, properly reinstall the
drives as indicated and:
If a bad power cable connection exists:
Press the F1 key to restart the server with the drive array disabled.
Press the F2 key to use the drives as configured and lose all the data on
them.
Troubleshooting
273