Performance Data; Scsi Port X Drive Id Y Failed - Replace (Failure Message); Scsi Port X, Drive Id Y Firmware Needs Upgrading; Scsi Port X, Drive Id Y Has Exceeded The Following Threshold(S) - HP ProLight Server Troubleshooting Manual

Hewlett-packard proliant servers troubleshooting guide
Table of Contents

Advertisement

If the error persists after completing steps 1 through 4, contact an HP authorized service provider.
5.

SCSI Port X Drive ID Y Failed - REPLACE (failure message)

Description: ADU
Action: Correct the condition that caused the error, if possible, or replace the drive.

SCSI Port X, Drive ID Y Firmware Needs Upgrading

Description: Drive firmware may cause problems and should be upgraded.
Action: Update the drive to the latest firmware version

SCSI Port X, Drive ID Y Has Exceeded the Following Threshold(s)

Description: The monitor and performance threshold for this drive has been violated.
Action: Check and resolve the threshold that has been violated.

SCSI Port X, Drive ID Y is not Stamped for Monitoring

Description: The drive has not been stamped with monitor and performance features.
Action: To stamp without destroying the current configuration:
Run ACU
1.
Change the array accelerator size and save the configuration.
2.
Change the array accelerator back to the original size and save again.
3.
This should cause ACU to stamp the drive with monitoring and performance features.

SCSI Port X, Drive ID Y May Have a Loose Connection...

...SOLUTION: Turn the system off and attempt to reattach any loose connections. If this does not work, replace the
cable(s) and connection(s).
Description: SMART is unable to communicate with the drive, because the cable is not securely
connected, or the drive cage connection has failed.
Action:
Power down the system.
1.
Reconnect the cable securely.
2.
Restart the system.
3.
If the problem persists, replace the cables and connectors as needed.
4.

SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match

Description: The copies of RIS on the drive do not match.
Action: Check for other errors. The drive may need to be replaced.
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected
in the Factory Monitor and Performance Data...
...SOLUTION: Please replace this drive when conditions permit.
("Array Diagnostic
("Array Configuration
Utility" on page 54).
Utility" on page 63) detected a drive failure.
("Firmware
maintenance" on page 65).
Error messages 85