SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match

Description: The copies of RIS on the drive do not match.
Action: Check for other errors. The drive may need to be replaced.
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected
in the Factory Monitor and Performance Data...
...SOLUTION: Please replace this drive when conditions permit.
Description: A predictive failure warning for this hard drive has been generated,
indicating that a drive failure is imminent.
Action: Replace this drive at the earliest opportunity. Refer to the server
documentation for drive replacement information before performing this
operation.
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected
in the Power Monitor and Performance Data...
...SOLUTION: Please replace this drive when conditions permit.
Description: A predictive failure warning for this hard drive has been generated,
indicating a drive failure is imminent.
Action: Replace this drive at the earliest opportunity. Refer to the server
documentation for drive replacement information before performing this
operation.

SCSI Port X, Drive ID Y Was Replaced On a Good Volume: (failure message)

Description: ADU found this drive was replaced, even though no problem
occurred with the volume.
Action: No action is required.