Needed - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

(5) Configuration information indicates drives were configured on a controller with a newer
firmware version.
Audible Beeps: None
Possible Cause: Drive array configuration not detected.
Action:
Run ACU ("Array Configuration Utility" on page
Power down the system and check SCSI cable connections to be sure the
drives are connected properly.
Run ADU ("Array Diagnostic Utility" on page
unknown. Then, turn the system power off and move the drives to their
original positions.
To avoid data loss, reconnect the drives to the original controller or upgrade
the controller firmware to the version on the original controller (or higher)
using Options ROMPaq.
1786-Slot 1 Drive Array Recovery Needed...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery
of data to drive.
Audible Beeps: None
Possible Cause: A failed or replacement drive has not yet been rebuilt.
Action:
Perform one of the following actions:
Press the F1 key to continue with recovery of data to the drive. Data will
be automatically restored to drive X when a failed drive has been
replaced, or to the original drive if it is working again without errors.
Press the F2 key to continue without recovery of data to the drive. The
failed drive will not be rebuilt and the system will continue to operate in
a failed state of Interim Data Recovery Mode.
Troubleshooting
115
).
126
) if previous positions are
271

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml370 g4

Table of Contents