1611-Fan Failure Detected; 1611-Fan X Failure Detected (Fan Zone Cpu) - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

Troubleshooting
253
Audible Beeps: None
Possible Cause: Required fan not spinning.
Action: Replace the failed fan to provide redundancy, if applicable.

1611-Fan Failure Detected

Audible Beeps: 2 short
Possible Cause: Required fan not installed or spinning.
Action:
1. Check the fans to be sure they are working.
2. Be sure each fan cable is properly connected and each fan is properly seated.
3. If the problem persists, replace the failed fans.

1611-Fan x Failure Detected (Fan Zone CPU)

Audible Beeps: 2 short
Possible Cause: Required fan not installed or spinning.
Action:
1. Check the fans to be sure they are working.
2. Be sure each fan cable is properly connected, if applicable, and each fan is
properly seated.
3. If the problem persists, replace the failed fans.