Controller Is Located In Special "Video" Slot; Controller Is Not Configured; Controller Reported Post Error. Error Code: X; Controller Restarted With A Signature Of Zero - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

Controller is Located in Special "Video" Slot

Description: Controller is installed in the slot for special video control signals. If
the controller is used in this slot, LED indicators on front panel may not function
properly.
Action: Install the controller into a different slot, and run the server setup utility
to configure NVRAM. Then, run ACU to configure the controller.

Controller Is Not Configured

Description: Controller is not configured. If the controller was previously
configured and you change drive locations, there may be a problem with
placement of the drives. ADU examines each physical drive and looks for drives
that have been moved to a different drive bay.
Action: Look for messages indicating which drives have been moved. If none are
displayed and drive swapping did not occur, run ACU ("Array Configuration
Utility" on page 115) to configure the controller and server setup utility to
configure NVRAM. Do not run either utility if you believe drive swapping has
occurred.

Controller Reported POST Error. Error Code: X

Description: The controller returned an error from its internal POST.
Action: Replace the controller.

Controller Restarted with a Signature of Zero

Description: ADU did not find a valid configuration signature to use to get the
data. NVRAM may not be present (unconfigured) or the signature present in
NVRAM may not match the signature on the controller.
Action: Run the server setup utility to configure the controller and NVRAM.
Troubleshooting
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml370 g4

Table of Contents