1777-Slot X Drive Array - Proliant Drive Storage Enclosure Problem Detected - HP ProLiant ML370 Generation 4 Reference And Troubleshooting Manual

Hide thumbs Also See for ProLiant ML370 Generation 4:
Table of Contents

Advertisement

268
HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
1777-Slot X Drive Array - ProLiant Drive Storage Enclosure Problem
Detected...
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
Check cooling fan operation by placing hand over fan.
Be sure the internal plenum cooling fan in tower servers or storage systems is
operational. If fan is not operating, check for obstructions and check all
internal connections.
Replace unit side panel if removed.
Check the LEDs. If the ProLiant Storage System power LED is amber
instead of green, this indicates a redundant power supply failure.
If the message indicates to check SCSI cables:
a. Compare the cabling against the diagrams in the HP Smart Array
b. If the routing is correct, replace cables on the specified port until the
Controller User Guide.
POST error message is eliminated.