Physical Interface
9.7.2

Output Lines

The camera is equipped with four physical output lines designated as Output Line 1, Output Line 2,
Output Line 3, and Output Line 4. The output lines are accessed via the 12-pin receptacle on the
back of the camera.
As shown in the I/O schematic, each output line is opto-isolated. The minimum VCC that must be
applied is +5 VDC and the maximum is +24 VDC. The maximum current allowed through an output
circuit is 100 mA.
A conducting transistor means a logical one and a non-conducting transistor means a logical zero.
Figure 28 shows a typical circuit you can use to monitor an output line with a voltage signal. The
circuit in Figure 28 is monitoring output line 1.
Fig. 28: Typical Voltage Output Circuit