Physical Interface

9.7 Input and Output Lines

9.7.1

Input Lines

The camera is equipped with two physical input lines designated as Input Line 1 and Input Line 2.
The input lines are accessed via the 12-pin receptacle on the back of the camera.
As shown in the I/O line schematic, each input line is opto-isolated. For each line, the minimum input
voltage to indicate a logical one is +5 VDC and the maximum is +24 VDC. An input voltage less
than +5 VDC means a logical zero. The current draw for each input line is between 5 and 15 mA.
Figure 27 shows an example of a typical circuit you can use to input a signal into the camera.
By default, Input Line 1 is assigned to receive an external hardware trigger (ExTrig) signal that can
be used to control the start of image acquisition.
Fig. 27: Typical Input Circuit
For more information about input line pin assignments and pin numbering, see Section 9.2 on
page
102.
For more information about how to use an ExTrig signal to control acquisition start, see Section 10.3
on
page
120.
For more information about configuring the input lines, see Section 12.1 on
page
165.