Physical Interface
Figure 29 shows a typical circuit you can use to monitor an output line with an LED or an opto-
coupler. In this example, the voltage for the external circuit is +24 VDC. Current in the circuit is
limited by an external resistor. The circuit in Figure 29 is monitoring output line 1.
Fig. 29: Typical LED Output Signal
By default, the camera's exposure active (ExpAc) signal is assigned to Output Line 1. The exposure
active signal indicates when exposure is taking place.
By default, the camera's trigger ready (TrigRdy) is assigned to Output Line 2. The trigger ready
signal goes high to indicate the earliest point at which exposure start for the next frame can be
triggered.
The assignment of camera output signals to physical output lines can be changed by the user.
For more information about output line pin assignments and pin numbering, see Section 9.2 on
page
102.
For more information about the exposure active signal, see Section Section 10.7 on
page
134.
For more information about the trigger ready signal, see Section Section 10.6 on
page
132.
For more information about assigning camera output signals to physical output lines, see
Section 12.2.1 on
page
167.