CDM-800 Gateway Router
Rear Panel Connections
3.3.3
48V Direct Current (DC) Power Interface (Optional)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.3.3.1
DC Operation – Applying Power
 
 
 
 
 
 
 
 
 
 
To apply DC power to the CDM‐800: 
 
First,  connect  the  user‐supplied  (+)  and  (–)  DC  power  leads  to  their  respective 
terminals. Number 18 AWG minimum wires are recommended.  
 
Then, connect the user‐supplied DC power leads to the power source. 
 
Finally, switch the unit ON.  
Feature
Input Power 
Input Voltage 
Connector Type
Fuse Protection 

Figure 3-8. CDM-800 DC Power Interface

Figure 3-9. Applying DC Power to the CDM-800

3–13
Description
1
On / Off Switch
2
Screw‐in Fuse Holders / Receptacles
3
Power Terminal Block 
  
DC Power Specifications 
25W (typical)
245W (maximum with BUC) 
48V DC, nominal
(36V to 60V) 
Terminal Block
(2X) 20mm Slow‐blow type fuses:
T3A (3.0A) Main  
T5A (5.0A) (BUC) 
Revision 1
MN-CDM800