CDM-800 Gateway Router
Ethernet-based Remote Product Management
Modem
Unit Name – The product (e.g., CDM‐800) is identified here. 
 
System Contact / System Location – E‐mail and telephone contact information for Comtech 
EF Data Customer Support are provided here.  
 
 
Enter the desired settings. Click [Submit] to save. 
 
Set Time (hh:mm:ss) – Use the HH:MM:SS time format to set the time, where HH=hour [00 
to 23]; MM=minutes [00 to 59]; and SS=seconds [00 to 59]). 
 
Set Date (dd/mm/yy) – Use the DD/MM/YY European time format to set the date, where 
DD=day [01 to 31]; MM=month [01 to 12]; and YY=year [00 to 99]. 
 
Set the time and date, and then click [Submit] to save. 
 
Circuit ID – Enter a Circuit ID string consisting of 4 to 24 characters, and then click [Submit] 
to save. 
 
G.703 Clock Extended Mode – Use the drop‐down menu to select this operating mode as Off 
or On, and then click [Submit] to save. 
 
10 MHz Internal Adjustment – Enter a value from (‐)999 to (+)999 to set the adjustment for 
the Internal 10 MHz High Stability Reference, and then click [Submit] to save. 
 
Test Mode – Use the drop‐down menu to select this operating mode as follows: 
 
o Normal Mode – This mode clears any test modes or loopbacks, and returns the unit to its  
operational state. 
 
o Tx CW – This test mode forces the modulator to transmit a pure carrier (unmodulated).  
 
o Tx Alt 1/0 – This test mode forces the modulator to transmit a carrier modulated with an 
alternating 1,0,1,0 pattern, at the currently selected symbol rate. This causes two discrete 
spectral lines to appear, spaced at +/‐ half the symbol rate, about the carrier frequency. 
Use this mode to check the carrier suppression of the modulator. 
 
Select the desired mode. Click [Submit] to save. 
Save/Load Configuration
This section allows the user to save, and then load (recall) up to 10 configuration sets: 
 
To save a configuration set:  
 
o First, adjust all operational configuration parameters to suit. 
 