Staff/duty stations
108
places staff normal calls, has no audio capability, and cannot be
used to communicate with staff members at staff consoles or
annunciators.
Figure 41: Call station with relay (shown without pull cord)
The model HC-PB2-CALLR call station has a latching relay that can
be used to start an elapsed timer, such as what is used on a cardiac
arrest clock. Other uses at your facility may include lighting dome
lights by patient bathrooms, releasing locks on intensive care unit
doors to provide easier access for emergency personnel, or
triggering automated announcements over a facility's loudspeaker
system.
Caution:
The relay contact is pulsed to flash the passive dome light.
This may not be appropriate for use with other devices.
1.
Press the Call button on the call station (or pull the cord) to send
a staff normal call to staff consoles and annunciators.
Pressing the Call button (or pulling the cord) causes the
following to happen:
lights by the station's Call button and by any linked Call
button turn on to confirm nurse call placement
The call assurance tone sounds at any associated patient
or staff/duty station.
Associated corridor and zone lights show a steady white.
Staff normal tones sound at staff consoles and unit
annunciators, and at stations with staff follow active.
A staff normal nurse call row appears on the Call screen on
staff consoles and unit annunciators.
Note:
A staff normal call is cleared from the system when a staff
member answers the call at a staff console or annunciator.