Section 2: Installation and Setup
2.2.7 Advanced Optical Alignment
Boresight Alignment Procedure
1. Display the Boresight Test Pattern by pressing the T
keypad and press the soft key that displays Test on the LCD display, then U
Boresight, then Enter, see
2. Focus the image on cross-hair pattern I. Evaluate the focus on cross-hair image II and III. If all 3 images
are in focus, no further action is required. If boresight is required see step 3.
3. If boresight is required, refer to
on the lens mount affect the corresponding cross-hairs on the test pattern.
4. Use a 5mm Allen™ key to loosen the 3 locking setscrews on the lens mount, see
Locations, below. NOTE: The setscrews must be backed out several turns, so that they do not contact the
inner lens mount plate.
2-18
F
2-13 - F
IGURE
OLDED
Figure 2-14 - Boresight
F
2-14 - B
IGURE
ORESIGHT
Figure 2-15 - Cross-Hair Pattern
O
P
PTICAL
ATH
key on the remote keypad or use the built-in
EST
Pattern.
P
ATTERN
to understand how the adjustment screws
to cycle to
A
K
P
RROW
EY
Figure 2-16 - Screw
M-Series User Manual