Advanced Optical Alignment - Christie M Series User Manual

M series
Hide thumbs Also See for M Series:
Table of Contents

Advertisement

2.2.7 Advanced Optical Alignment

Boresight Alignment Procedure
1. Display the Boresight Test Pattern by pressing the T
keypad and press the soft key that displays Test on the LCD display, then U
Boresight, then Enter, see
2. Focus the image on cross-hair pattern I. Evaluate the focus on cross-hair image II and III. If all 3 images
are in focus, no further action is required. If boresight is required see step 3.
3. If boresight is required, refer to
on the lens mount affect the corresponding cross-hairs on the test pattern.
19) may be under a plastic cap, remove and retain before adjusting.
4. Use a 5mm Allen™ key to loosen the 3 locking setscrews on the lens mount, see
Locations, below.
inner lens mount plate.
M Series User Manual
020-100009-05 Rev. 1 (09-2010)
F
2-16 F
IGURE
Figure 2-17 Boresight
F
2-17 B
IGURE
Figure 2-18 Cross-Hair Pattern
The setscrews must be backed out several turns, so that they do not contact the
NOTE:
O
P
OLDED
PTICAL
ATH
key on the remote keypad or use the built-in
EST
Pattern.
P
ORESIGHT
ATTERN
to understand how the adjustment screws
Section 2: Installation and Setup
A
K
to cycle to
P
RROW
EY
The capscrew,
NOTE:
Figure 2-19 Screw
(Figure 2-
2-17