Serial Flow Control - Determines whether software flow control or no flow control is used when transmitting
and receiving data on the serial port.
• PROJECTOR ADDRESS:
Enter a three-digit number (such as "001") to assign or change a number to the projector currently in use. If the
current projector already has a number assigned, that number will appear here (for example "004" in the menu
shown below. Numerical identity for projectors enables you to communicate with a single projector within a
multiple-projector application (see also P
make a mistake in assigning or changing the projector number, press E
projectors are being used and you want to adjust the color for individual projectors to create one seamless
image, you must assign different numbers for each projector to allow switching back and forth between
projectors while adjustments are being made.
• NETWORK ROUTING:
NOTE: Not applicable for stand-alone projectors or simple serial networks with only one type of controller
and linking.
Separate - Select "Separate" (factory default) to keep RS232, RS422 and Ethernet messages on their
respective paths instead of being broadcast to the other types of ports, refer to
Figure 2-19 - Connecting RS232
RS232 and RS422 Joined - Messages originating from an RS232 or RS422 controller will be relayed to all
RS232or RS422 ports. Any Ethernet communication, however, will not.
RS232 and Ethernet Joined - Messages to and from the RS232 ports will also be relayed to the Ethernet port,
and vice versa. Any RS422 communications will be isolated. In the case of multiple Ethernet sessions over the
single Ethernet connector, input on the RS232 port will be relayed to all Ethernet sessions; however, input
from any Ethernet session will only be relayed to the RS232 ports.
All Joined - All messages reach all ports, regardless of type in the case of multiple Ethernet sessions, input on
one Ethernet session will be relayed to all other Ethernet sessions as well as to the RS232 and RS422 ports.
ETHERNET SETTINGS:
NOTE: Recommended for network administrators only.
• IP ADDRESS:
Enter a valid and unique IP address for use on the network to which the projector is currently connected. This
address will overwrite any previous IP address such as the projector's factory-defined default. It takes
approximately 10 seconds for the projector to respond at its new address.
• TCP PORT:
On some Ethernet networks, firewall restrictions may require that the port number of the projector be changed
from its default of 3002. If so, enter a new valid port number here. It is highly recommended not to use a port #
below 1000, as these ports are typically reserved for and used by common IP applications.
M-Series User Manual
020-100009-02 Rev. 1 (04-2009)
key in,
3.1 Using the Remote Keypad or Built-In
ROJ
F
3-32 - N
IGURE
ETWORK
to
Figure 2-24 - Communicating To All
to cancel. NOTE: When multiple
XIT
R
L
OUTING
IST
Section 2 Installation and Setup,
Ports.
Section 3: Operation
Keypad). If you
3-35