Adjusting Front Position Of The Fuser Unit (Adjusting Lateral Squareness) - Kyocera KM-3050 Service Manual

Hide thumbs Also See for KM-3050:
Table of Contents

Advertisement

2GN/2GP/2GR

(7) Adjusting front position of the fuser unit (adjusting lateral squareness)

Follow the procedure below if the drum is not parallel to the fuser unit and therefore paper is not fed straight to the fuser
section and the trailing edge of image on either the front or rear side becomes longer.
Procedure
Place the original on the contact
glass.
Press the start key and make
a test copy at 100% magnification.
Is the image correct?
1-5-34
Start
No
Yes
End
Original
Figure 1-5-69
Tighten the two screws. Refit the front
left cover and close the front cover.
Open the front cover and remove the
front left cover (see page 1-5-13).
Loosen the screw holding each of the
fuser unit and adjusting spacer.
For copy example 1:
Move the adjusting spacer in the direction
of the black arrow (
) to raise the front
position of the fuser unit.
For copy example 2:
Move the adjusting spacer in the direction
of the white arrow (
) to lower the front
position of the fuser unit.
Screw
Screw
Figure 1-5-70
Copy
Copy
example 1
example 2
Fuser unit
Adjusting spacer