Kyocera KM-3050 Service Manual page 72

Hide thumbs Also See for KM-3050:
Table of Contents

Advertisement

2GN/2GP/2GR
Maintenance
item No.
Checking/clearing the developing drive time
U157
Description
Displays the developing drive time for checking, or clearing a figure, which is used as a reference when cor-
recting the toner control.
Purpose
To check the developing drive time after replacing the developing unit.
Method
Press the start key. The developing drive time is displayed in minutes.
Clearing
1. Press the clear key.
2. Press the start key. The time is cleared.
Setting
1. Enter a drive time (in minutes) using the numeric keys.
2. Press the start key. The time is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking the developing count
U158
Description
Displays the developing count for checking.
Purpose
To check the developing count after replacing the developing unit.
Method
Press the start key. The developing counter count is displayed.
Setting
1. Change the setting using the +/- or numeric keys.
2. Press the start key. The count is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the fuser control temperature
U161
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- or numeric keys.
Display
DRIVE START TEMP
READY CONTROL T
PRINT CONTROL T
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-42
Description
Description
Driving start temperature when
warm-up starts
Control temperature for displaying
[Ready for copying.]
Control temperature during printing
Setting range
Initial setting
°
175 (30 ppm)
0 to 255 (
C)
185 (40/50 ppm)
°
190 (30 ppm)
0 to 255 (
C)
200 (40/50 ppm)
°
190 (30 ppm)
0 to 255 (
C)
200 (40/50 ppm)