Adjustment-free variable resistors (VR)

The variable resistors listed below are set at the factory prior to shipping and cannot be adjusted in the field.
High voltage PWB: VR2, VR42, VR201, VR204
1-6-3

Remarks on main PWB replacement

When replacing the main PWB, remove EEPROM from the main PWB that has been removed and then reattach it to the
new main PWB.
1-6-4

Remarks on scanner PWB replacement

When replacing the scanner PWB, remove the EEPROM from the scanner PWB that has been removed and then reattach
it to the new scanner PWB.
1-6-2
EEPROM
Main PWB
Figure 1-6-2
EEPROM
Figure 1-6-3
Scanner PWB