Kyocera KM-3050 Service Manual page 118

Hide thumbs Also See for KM-3050:
Table of Contents

Advertisement

2GN/2GP/2GR
Section
Description
Feedshift
52
section
Misfeed in feedshift
section
Duplex
60
section
Duplex paper convey-
ing section 1
61
Duplex paper convey-
ing section 2
Optional
70
DP
No original feed
71
An original jam in the
original feed/conveying
section 1
72
An original jam in the
original feed/conveying
section 2
73
An original jam in the
original conveying sec-
tion
74
An original jam in the
original registration
section
1-4-6
Conditions
The feedshift switch (FSSW) does not turn on within
specified time of the start of eject motor (EM) reverse
rotation.
During paper switchback operation, the feedshift switch
(FSSW) does not turn off within specified time of the its
turning on.
The feedshift switch (FSSW) does not turn off within
specified time of the registration switch (RSW) turning off.
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
The duplex paper conveying switch (DUPPCSW) does
not turn on within specified time of the feedshift switch
(FSSW) turning on.
The duplex paper conveying switch (DUPPCSW) does
not turn off within specified time of the feedshift switch
(FSSW) turning off.
The feed switch 1 (FSW1) does not turn on within speci-
fied time of the duplex paper conveying switch (DUP-
PCSW) turning on.
The feed switch 1 (FSW1) does not turn off within speci-
fied time of the duplex paper conveying switch (DUP-
PCSW) turning off.
The original feed switch (OFSW) does not turn on within
specified time during the first sheet feeding.
The original feed switch (OFSW) does not turn on within
specified time during the second sheet feeding.
DP timing switch 2 (DPTSW2) does not turn off within
specified time.
The original feed switch (OFSW) and original registration
switch (ORSW) does not turn off within specified time.
DP timing switch 1 (DPTSW1) does not turn off within
specified time.
The original registration switch (ORSW) does not turn on
within specified time and after 5 retries.
Specified time
1545 ms (30 ppm)/
1196 ms (40/50 ppm)
2989 ms (30 ppm)/
2313 ms (40/50 ppm)
2899 ms (30 ppm)/
2243 ms (40/50 ppm)
2899 ms (30 ppm)/
2243 ms (40/50 ppm)
2837 ms (30 ppm)/
2196 ms (40/50 ppm)
2837 ms (30 ppm)/
2196 ms (40/50 ppm)
1994 ms (30 ppm)/
1543 ms (40/50 ppm)
1994 ms (30 ppm)/
1543 ms (40/50 ppm)
2436 pulse
4430 pulse
2500 pulse
16675 pulse
4979 pulse
4979 pulse