2GN/2GP/2GR
2-1-6

Cleaning and charge erasing sections

The cleaning section consists of the cleaning blade that removes residual toner from the drum surface after the transfer
process, and the cleaning spiral that carries the residual toner back to the waste toner box.
The cleaning lamp (CL) consists of LEDs and removes residual charge on the drum before main charging.
Also the toner quantity in the waste toner box is sensed with the overflow sensor (OFS).
Cleaning spiral
Cleaning lamp (CL)
Cleaning roller
Cleaning blade
Drum
Figure 2-1-19 Cleaning and charge erasing sections
CL
YC9-B7
CL
Drum
EPWB
OFS
OFS
YC6-B4
Figure 2-1-20 Cleaning and charge erasing sections block diagram